CIRCUIT BREAKER MAG IK60N 2 P 6A CURVE-C A9F89206 SCHNEIDER

49,19 (IVA incluido)

SKU: A9F89206 Categories: , Tag:

Circuit Breaker Magnetothermal IK60N 2 P 6A CURVA-C A9F89206 SCHNEIDER.

Technical Data

F.T.
Pide más información

Description

DESCRIPTION CIRCUIT BREAKER MAG IK60N 2 P 6A CURVE-C A9F89206 SCHNEIDER.

iC60H Acti 9, 2P, 6A, C-curve, IP20, thermal-magnetic circuit breaker, suitable for disconnecting, contact position indicator, handle control, trip indicator, fixed mounting, DIN rail mounting, without earth leakage protection, measures 85x18x78.5mm, weighs 0.215kg and is white in color. Breaking capacity: 10000 A Icn according to IEC 60898-1, 230 V AC 50/60 Hz, 15 kA Icu according to IEC 60947-2, 220…240 V AC 50/60 Hz, 15 kA Icu according to EN 60947-2, 220…240 V AC 50/60 Hz, 15 kA Icu according to EN 60947-2, 220…240 V AC 50/60 Hz, 20 kA Icu in accordance with IEC 60947-2, 12…60 V DC, 30 kA Icu in accordance with EN 60947-2, 100…133 V AC 50/60 Hz, 10000 A Icn in accordance with EN 60898-1, 230 V AC 50/60 Hz, 42 kA Icu in accordance with IEC 60947-2, 12…60 V AC 50/60 Hz, 42 kA Icu in accordance with IEC 60947-2, 12…60 V AC 50/60 Hz, 15 kA Icu according to EN 60947-2, 72 V DC, 20 kA Icu according to EN 60947-2, 12…60 V DC, 30 kA Icu according to IEC 60947-2, 100…133 V AC 50/60 Hz, 42 kA Icu according to EN 60947-2, 12…133 V AC 50/60 Hz, 42 kA Icu according to EN 60947-2, 12…60 V AC 50/60 Hz, 15 kA Icu according to IEC 60947-2, 72 V DC, utilization category A according to EN 60947-2, category A according to IEC 60947-2, suitable for isolating according to EN 60898-1, according to EN 60947-2, according to IEC 60947-2 and according to IEC 60898-1. Standards: IEC 60898-1, EN 60898-1, EN 60947-2, IEC 60947-2.

Circuit breaker magnetothermal Schneider IC60H 2P 6A Curve C – Schneider A9F89206. Degree of protection: IP20. Color: white. Weight: 0.5 kg. Rated current (In) 25 A. Type of network: AC/DC.

Brand: Schneider.

TECHNICAL CHARACTERISTICS

Technical information
Principal
Device applicationFor current> 0.1 A
RangeActi9
Product nameActi 9 iC60 RCBO
Type of product or componentMiniature circuit breaker
Short name of the deviceIC60H
Number of poles2P
Number of protected poles2
[In] Rated current6 A
Type of networkDirect current
AC
Firing unit technologyThermal-magnetic
Curve codeC
Cutting capacity10000 A Icn at 400 V AC 50/60 Hz according to EN/IEC 60898-1
42 kA Icu at 12…60 V AC 50/60 Hz according to Icu
10 kA Icu at 440 V AC 50/60 Hz according to Icu
15 kA Icu at 380…415 V AC 50/60 Hz according to Icu
30 kA Icu at 220…240 V AC 50/60 Hz according to Icu
15 kA Icu at <= 125 V direct current according to Icu
42 kA Icu at 100…133 V AC 50/60 Hz according to Icu
Job CategoryCategory A according to HB1
Category A according to En> 50 A
Sectionalizing powerYes according to EN 60898-1
Yes according to HB1
Yes according to IEC 60898-1
Yes according to En> 50 A
StandardsHB1
At> 50 A
EN 60898-1
IEC 60898-1
Complementary
Network frequency50/60 Hz
Magnetic bond limit8 x In +/- 20%.
[Ics] shear strength in service15 kA 50 % according to HB1 – 220…240 V AC 50/60 Hz
7.5 kA 50 % according to HB1 – 380…415 V AC 50/60 Hz
5 kA 50 % according to HB1 – 440 V AC 50/60 Hz
15 kA 50 % according to En> 50 A – 220…240 V AC 50/60 Hz
7.5 kA 50 % according to En> 50 A – 380…415 V AC 50/60 Hz
5 kA 50 % according to En> 50 A – 440 V AC 50/60 Hz
7500 A 75 % according to EN 60898-1 – 400 V AC 50/60 Hz
7500 A 75 % according to IEC 60898-1 – 400 V AC 50/60 Hz
21 kA 50 % according to En> 50 A – 12…133 V AC 50/60 Hz
21 kA 50 % according to HB1 – 12…133 V AC 50/60 Hz
15 kA 100 % according to En> 50 A – 72…125 V direct current
15 kA 100 % according to HB1 – 72…125 V direct current
Type of limitation3 according to EN 60898-1
3 according to IEC 60898-1
[Ui] Rated insulation voltage500 V AC 50/60 Hz according to HB1
500 V AC 50/60 Hz according to En> 50 A
[Uimp] Resistance to voltage peaks6 kV according to HB1
6 kV according to En> 50 A
Contact position indicatorYes
Type of controlHandle
On-site signageTrigger indicator
Type of mountingFixed
Mounting bracketDIN rail
Compatibility of distribution block and comb-type busbarsUp or down, status 1 YES
9 mm steps4
Height85 mm
Width36 mm
Depth78.5 mm
Product weight0.25 kg
ColorWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Connections – terminalsSingle terminal – cable type: top or bottom) 1…25 mm² rigid
Single terminal – cable type: above or below) 1…16 mm² flexible
Stripped cable length for connecting terminals14 mm up or down connection
Tightening torque2 N.m up or down
Earth leakage protectionIndependent block
Environment
IP degree of protectionIP20 according to IEC 60529
IP20 according to EN 60529
Degree of contamination3 according to HB1
3 acorde a En> 50 A
Overvoltage categoryIV
Tropicalization2 according to IEC 60068-1
Relative humidity95 % at 55 °C
Maximum operating altitude0…2000 m
Ambient operating temperature-35…70 °C
Ambient storage temperature-40…85 °C

If you need automatics visit our automatics and differentials section.

Additional information

Fabricante

EAN-GTIN

3606480095016