Description
DESCRIPTION CIRCUIT BREAKER NG125N 4P 100A CURVE-C 18660 SCHNEIDER.
Circuit Breaker NG125N 4P 100A Schneider Curve C 18660.
Miniature MCB Acti 9, NG125N, 4P, 100A, C-curve, Thermal-magnetic, Rated current (In) 100 A at 40 °C, 0.96 kg. Breaking capacity: 20 kA Icu according to EN/IEC 60947-2, 440 V AC 50/60 Hz, 25 kA Icu according to EN/IEC 60947-2, 380…415 V AC 50/60 Hz, 50 kA Icu according to EN/IEC 60947-2, 220…240 V AC 50/60 Hz, 10 kA Icu according to EN/IEC 60947-2, 500 V AC 50/60 Hz, 20 kA Icu according to EN/IEC 60947-2, <= 500 V DC. Benefits: With the advantages of all the ease of a modular installation, the NG125 circuit breaker combines the performance and robustness required in the most demanding industrial installations. Applications: Protection in all industrial and tertiary buildings: Entrance protection in modular enclosures. Projections in power distribution panels.
Brand: Schneider.
TECHNICAL CHARACTERISTICS
Principal Product range | NG125 | Range | Acti9 | Product name | Acti 9 NG125LMA | Type of product or component | Miniature circuit breaker | Short name of the device | NG125N | Device application | For current> 0.1 A | Number of poles | 4P | Number of protected poles | 4 | [In] Rated current | 100 A at 40 °C | Type of network | Direct current AC | Firing unit technology | Thermal-magnetic | Curve code | C | Cutting capacity | 20 kA Icu at <= 500 V direct current according to Icu 10 kA Icu at 500 V AC 50/60 Hz according to Icu 20 kA Icu at 440 V AC 50/60 Hz according to Icu 25 kA Icu at 380…415 V AC 50/60 Hz according to Icu 50 kA Icu at 220…240 V AC 50/60 Hz in accordance with Icu | Job Category | Category A according to En> 50 A | Sectionalizing power | Yes according to En> 50 A |
Complementary Network frequency | 50/60 Hz | [Ue] Rated operating voltage | 380…415 V AC 50/60 Hz 500 V AC 50/60 Hz <= 500 V direct current 220…240 V AC 50/60 Hz 440 V AC 50/60 Hz | Magnetic bond limit | 8 x pol | [Ics] shear strength in service | 37.5 kA 75 % according to Icu – 220…240 V AC 50/60 Hz 18,75 kA 75 % according to Icu – 380…415 V AC 50/60 Hz 15 kA 75 % according to Icu – 440 V AC 50/60 Hz 7.5 kA 75 % according to Icu – 500 V AC 50/60 Hz 20 kA 100 % according to Icu – <= 500 V direct current | [Ui] Rated insulation voltage | 690 V AC 50/60 Hz in accordance with Icu | [Uimp] Resistance to voltage peaks | 8 kV according to Icu | Contact position indicator | Yes | Type of control | Manual trigger test Handle | On-site signage | On/off indication Trigger indicator | Type of mounting | Adjustable in clip | Mounting bracket | Symmetrical 35 mm DIN rail | Compatibility of distribution block and comb-type busbars | NO | 9 mm steps | 12 | Height | 103 mm | Width | 108 mm | Depth | 81 mm | Product weight | 0.96 kg | Mechanical durability | 20000 cycles | Electrical durability | 5000 cycles | Padlockable | With padlock | Description of locking options | Integrated padlock | Connections – terminals | Tunnel terminals16…70 mm² rigid type Tunnel type terminals10…50 mm² flexible | Stripped cable length for connecting terminals | 20 mm | Tightening torque | 6 N.m | Earth leakage protection | Independent block |
Environment Standards | Icu | IP degree of protection | IP20 according to IEC 60529 | Degree of protection IK | IK05 according to EN/IEC 62263 | Degree of contamination | 3 acorde a En> 50 A | Overvoltage category | IV | Tropicalization | 2 according to IEC 60068-1 | Relative humidity | 95 % at 55 °C | Ambient operating temperature | -30…70 °C | Ambient storage temperature | -40…70 °C |
|
If you need automatics visit our automatics and differentials section.